PASA Attributes

Name

Units

Default Value

Validation Rule

Description

Compute Multi-area Reliability Indices

Yes/No

0

In (0,-1)

Master switch for computation of reliability indices LOLP, LOLE, etc across multiple areas.

Compute Reliability Indices

Yes/No

0

In (0,-1)

Master switch for computation of reliability indices LOLP, LOLE, etc.

Constraints Enabled

Yes/No

-1

In (0,-1)

If transmission line constraints are enabled in PASA.

Energy Objective

%

0

Between 0 And 100

Relative contribution of energy margins to PASA objective function

Include Contract Generation

Yes/No

0

In (0,-1)

Include physical contract generation capacity in PASA

Include Contract Load

Yes/No

0

In (0,-1)

Include physical contract load capacity in PASA

Include Demand Bids

Yes/No

0

In (0,-1)

Include demand bids are load in PASA

Include DSP

Yes/No

-1

In (0,-1)

Include demand-side participation in PASA

Include Market Purchases

Yes/No

0

In (0,-1)

Include market purchases as generation capacity in PASA

Interface Constraints Enabled

Yes/No

-1

In (0,-1)

If transmission interface constraints are enabled in PASA.

Maintenance Sculpting

%

0

Between 0 And 100

Level of sculpting of maintenance outages: Higher sculpting means outages are more concentrated in high reserve periods

Reliability Criterion

-

0

In (0,1)

Criterion used to select periods for Monte Carlo reliability analysis

Reliability LOLP Tolerance

-

0.01

>= 0

For reliability-based sampled chronology using LOLP criterion select intervals with LOLP at or above this level

Reliability Max Samples

h

1E+30

>= 1

For reliability-based sampled chronology select no more than this many hours per year

Step Type

-

1

In (0,1,2)

PASA step type: One period is modelled for each period of this type in horizon.

Stochastic Method

-

0

In (0,1,2,3)

Stochastic optimization method for PASA.

Transmission Detail

-

0

In (0,1,2)

Definition of maintenance area for PASA.

Write Outage Text Files

Yes/No

0

In (0,-1)

If outage patterns should be written to text files

Write Reliability Text Files

Yes/No

0

In (0,-1)

If the periods selected for Monte Carlo reliability analysis should be written to text files