Production Attributes Reference

This page documents the PLEXOS Production class attributes and their default values, validation rules, and descriptions.

To look at the open access PLEXOS documentation, go to PLEXOS Production Index.

Use this reference when setting configuration values through PlexosDB attributes, for example with add_attribute, get_attribute, and list_attributes.

Production Attributes

Name

Units

Default Value

Validation Rule

Description

Battery Station Aggregation Mode

-

0

In (0,1,2)

Automatically create Battery Station objects by aggregating Batteries

Capacity Factor Constraint Basis

-

0

In (0,1)

Basis for capacity factor constraints.

Cooling States Enabled

Yes/No

-1

In (0,-1)

If generator unit cooling states are enabled

Dispatch by Battery Station

Yes/No

-1

In (0,-1)

If batteries should be aggregated through manual or automatic battery stations for dispatch.

Dispatch by Power Station

Yes/No

-1

In (0,-1)

If generators in power stations should be treated in aggregate for dispatch.

DP Capacity Factor Error Threshold

%

20

>= 0

Error in DP capacity factor compared to MT Schedule capacity factor below which the DP solution is accepted

DP Capacity Factor Threshold

%

20

>= 0

Minimum capacity factor for generators to be dispatched by the DP

Forced Outage Relaxes Min Down Time

Yes/No

0

In (0,-1)

If ramp constraints should all be formulated upfront rather than checked iteratively.

Formulate Ramp Upfront

Yes/No

-1

In (0,-1)

If ramp constraints should all be formulated upfront rather than checked iteratively.

Formulate Upfront

Yes/No

-1

In (0,-1)

If production constraints should all be formulated upfront rather than checked iteratively.

Fuel Use Function Precision

-

0

>= 0

Precision for calculation of linear approximation to fuel function.

Gas Demand Resolution

-

0

In (0,1,2)

Resolution of input gas demands

Heat Rate Detail

-

0

In (0,1,2)

Level of detail for Generator heat rate modelling

Heat Rate Error Method

-

2

In (0,1,2,3,4)

Method for handling non-convex heat rate functions.

Increment and Decrement

Yes/No

-1

In (0,-1)

If simultaneous closure of increment and decrement bids/offers around a base is allowed

Integers in Look-ahead

-

1

In (0,1,2)

Controls when the look-ahead contains integers for unit commitment and other decisions.

Max Heat Rate Tranches

-

10

Between 1 And 100

Maximum number of tranches in the fuel function piecewise linear approximation

Min Heat Rate Tranche Size

-

0

>= 0

Minimum tranche size in fuel function piecewise linear approximation

Power Station Aggregation Mode

-

0

In (0,1,2)

Automatically create Power Station objects by aggregating Generators

Pump and Generate

Yes/No

-1

In (0,-1)

If pumped storage/battery is allowed to pump/charge and generate/discharge simultaneously

Ramping Constraints Enabled

Yes/No

-1

In (0,-1)

If facility ramping constraints are modeled

Rounded Relaxation Commitment Model

-

0

In (0,1)

Determines if the unit commitment decisions are made centrally or by self-commitment

Rounded Relaxation End Threshold

-

0.75

<= 1

End value for [Rounding Up Threshold] when Rounded Relaxation is running self-tune.

Rounded Relaxation Start Threshold

-

0.25

>= 0

Start value for [Rounding Up Threshold] when Rounded Relaxation is running self-tune.

Rounded Relaxation Threshold Increment

-

0.05

>= 0.01

Increment value for [Rounding Up Threshold] when Rounded Relaxation is running self-tune.

Rounded Relaxation Tuning

Yes/No

0

In (0,-1)

If the Rounded Relaxation method should self-tune the [Rounding Up Threshold].

Rounding Up Threshold

-

0.5

Between 0 And 1

Threshold at which non-integers are rounded up.

Run Up and Down Enabled

Yes/No

-1

In (0,-1)

If generator run up and run down are modeled

Start and Stop Enabled

Yes/No

-1

In (0,-1)

If facility start up and shut down are modeled

Start Cost Method

-

0

In (0,1)

Method for handling start costs in the mathematical formulation (integrate into the formulation, or calculate ex-post)

Transitions Enabled

Yes/No

-1

In (0,-1)

If generator transitions are modeled

Unit Commitment Heat Rate Detail

Yes/No

-1

In (0,-1)

If modeling fully detailed heat rates for unit commitment. Otherwise perform a two-pass UC/ED.

Unit Commitment Optimality

-

0

In (0,1,2,3)

Unit commitment integerization scheme.

Warm Up Process Enabled

Yes/No

-1

In (0,-1)

If modeling of Facility Warm Up Process is enabled