Transmission Attributes Reference¶
This page documents the PLEXOS Transmission class attributes and their default values, validation rules, and descriptions.
To look at the open access PLEXOS documentation, go to PLEXOS Transmission Index.
Use this reference when setting configuration values through PlexosDB
attributes, for example with add_attribute, get_attribute, and
list_attributes.
Transmission Attributes¶
Name |
Units |
Default Value |
Validation Rule |
Description |
|---|---|---|---|---|
Allow Dump Energy |
Yes/No |
-1 |
In (0,-1) |
Model Dump Energy in OPF |
Allow Unserved Energy |
Yes/No |
-1 |
In (0,-1) |
Model Unserved Energy in OPF |
Bound Node Phase Angles |
Yes/No |
0 |
In (0,-1) |
If the Node [Phase Angle] values are subject to bounds in absolute value. |
Cache Transmission Matrices |
Yes/No |
0 |
In (0,-1) |
Cache the transmission matrices to disk for future use. |
Calculate Node LPF from Load |
- |
0 |
In (0,1) |
Automatically calculate Node LPF from input Load property |
Commitment PTDF Threshold |
- |
0 |
>= 0 |
Minimum absolute value of PTDF coefficient in commitment solves. |
Constraint Limit Penalty |
$/MWh |
-1 |
Penalty for exceeding line and transformer limits. |
|
Constraint Voltage Threshold |
kV |
0 |
>= 0 |
Voltage level at which thermal limits are modelled. |
Constraints Enabled |
Yes/No |
-1 |
In (0,-1) |
If transmission line constraints are enabled. |
Contingency Limit Penalty |
$/MWh |
-1 |
Penalty for exceeding contingency flow limits. |
|
Contingency Monitoring Threshold |
% |
100 |
Between 0 And 100 |
Monitor only this percentage of most affected Line/Transformer/Interface flows. |
Convergence Report Level |
- |
1 |
In (0,1,2) |
Level of screen reporting during transmission convergence iterations (none, normal, verbose) |
Detail |
- |
1 |
In (0,1,2) |
Level of detail used in transmission modeling |
Detect Non-physical Losses |
Yes/No |
0 |
In (0,-1) |
If non-physical losses should be detected (in the piecewise linear loss model) and removed via mixed-integer programming |
Energy Balance Violation Variables |
Yes/No |
0 |
In (0,-1) |
Include violation variables on the transmission system energy balance equations |
Enforce Limits On Lines In Interfaces |
Yes/No |
0 |
In (0,-1) |
If lines and transformers in interfaces should have their limits enforced regardless of voltage |
Enforce N-1 Contingencies |
Yes/No |
0 |
In (0,-1) |
If N-1 contingencies should be automatically enforced. |
Filter Limits |
Yes/No |
0 |
In (0,-1) |
If transmission limits are filtered using extreme flows from MT Schedule |
Flow PTDF Threshold |
- |
0.01 |
>= 0 |
Minimum absolute value of PTDF as coefficient in transmission flow constraints. |
Formulate Upfront |
Yes/No |
0 |
In (0,-1) |
If transmission constraints should all be formulated upfront rather than checked iteratively. |
Interface Constraints Enabled |
Yes/No |
-1 |
In (0,-1) |
If interface constraints are enabled. |
Interface Limit Penalty |
$/MWh |
-1 |
Penalty for exceeding interface flow limits. |
|
Internal VoLL |
$ |
100000 |
Between 0 And 1E+9 |
Value of Lost Load used internally |
Interruption Sharing |
Yes/No |
0 |
In (0,-1) |
If region interruption sharing is activated. |
Kron-reduced Model Input |
- |
0 |
In (0,1) |
Input properties and files written out for Kron-reduced model. |
Limit Bootstrap Initial Threshold |
- |
2 |
>= 0 |
Initial value of [Limit Threshold] during transmission constraint bootstrap phase. |
Limit Bootstrap Threshold Decrement |
- |
0.25 |
Between 0 And 1 |
[Limit Threshold] decrement used for each iteration of transmission bootstrap phase. |
Limit Threshold |
- |
0.95 |
Between 0 And 1 |
Line, Transformer, or Interface flow loading threshold above which limits are added. |
LODF Threshold |
- |
0.03 |
>= 0 |
Minimum absolute value of LODF to be used in contingency flow constraints. |
Loss Method |
- |
0 |
In (0,1,3,4,5) |
Formulation method used to model transmission losses. |
Loss Tolerance |
- |
1E-05 |
>= 0 |
Relative gap between real and modelled losses. |
Loss Voltage Threshold |
kV |
0 |
>= 0 |
Voltage level at which losses are modelled. |
Losses Enabled |
Yes/No |
0 |
In (0,-1) |
If transmission losses are enabled. |
Max Absolute Phase Angle |
rad |
6.28 |
Between 0 And 6.28318530717958 |
Maximum absolute value allowed for any Node [Phase Angle]. |
Max Embedded Loss Iterations |
- |
2 |
>= 0 |
Maximum number of iterations for removing embedded losses from load. |
Max Limit Iterations |
- |
1000 |
>= 0 |
Maximum number of iterations during any one call to enforce transmission limits. |
Max Loss Absolute Error |
- |
0 |
>= 0 |
Maximum allowed absolute error in the piecewise linear loss function. |
Max Loss Iterations |
- |
50 |
>= 1 |
Maximum number of iterations for converging the losses. |
Max Loss Relative Error |
- |
0 |
>= 0 |
Maximum allowed relative error in the piecewise linear loss function. |
Max Loss Tranches |
- |
100 |
>= 1 |
Maximum number of tranches in piecewise linear line loss function. |
MVA Base |
- |
100 |
>= 0 |
MVA base for AC line parameters. |
N-1 Contingency Voltage Threshold |
kV |
0 |
>= 0 |
Voltage level at which N-1 contingencies are automatically enforced. |
OPF Method |
- |
0 |
In (0,1) |
Method for solving optimal power flow. |
PTDF Method |
- |
0 |
In (0,1,2,3,4) |
Method for computation of shift factors |
Reactance Cut-off |
- |
0 |
Smallest allowable reactance when performing OPF. |
|
Rental Method |
- |
0 |
In (0,1) |
Method used to calculate transmission rentals |
Report All Interregional Flows |
Yes/No |
-1 |
In (0,-1) |
If line flows between regions should be reported regardless of kV. |
Report All Interzonal Flows |
Yes/No |
-1 |
In (0,-1) |
If line flows between zones should be reported regardless of kV. |
Report Enabled |
Yes/No |
-1 |
In (0,-1) |
If transmission reporting is enabled. |
Report Injection and Load Nodes |
Yes/No |
0 |
In (0,-1) |
If all injection and load buses (nodes) are reported on (regardless of voltage) |
Report Lines In Interfaces |
Yes/No |
0 |
In (0,-1) |
If all flows on lines selected interfaces are reported |
Report Voltage Threshold |
kV |
0 |
>= 0 |
Voltage level at which transmission reporting begins. |
SCUC Constraint Voltage Threshold |
kV |
0 |
>= 0 |
Voltage level at which SCUC line thermal limits are modelled. |
SCUC Enabled |
Yes/No |
0 |
In (0,-1) |
If security constrained unit commitment (SCUC) is enabled |
SCUC Interface Constraints Enabled |
Yes/No |
0 |
In (0,-1) |
If enabled interface constraints are monitored in SCUC. |
USE Threshold |
% |
100 |
Between 0 And 100 |
Formulates the [Unserved Energy] variables on the top x% nodes (highest load). |
Wheeling PTDF Threshold |
- |
0.05 |
>= 0 |
Minimum absolute value of PTDF as coefficient in wheeling definitions. |
Write Kron-reduced Model |
Yes/No |
0 |
In (0,-1) |
If write Kron-reduced model is enabled. |
Zero Limit Treatment |
- |
0 |
In (0,1) |
Treatment of AC elements with zero limits |