NameUnitsDefault ValueValidation RuleDescription
At a Time-0>= 0Number of day/week/months/years in each MT Schedule simulation step.
Block Count-3>= 1Number of load duration curve blocks in each day/week/month.
Chronology-2In (2,3,4,5)Type of chronology used.
Discount Period Type-2In (1,2,3,4,6,7)A unique discount factor will be computed for each of these periods.
Discount Rate%0>= 0Discount rate.
End Effects Method-1In (0,1)Method used to account for end of horizon discounting.
Last Block Count-0>= 0Number of load duration curve blocks in the last load duration curve of the horizon, or zero if same as Block Count.
LDC Pin Bottom--1>= -1Number of points at the bottom of the LDC that are pinned and cannot be aggregated into blocks.
LDC Pin Top--1>= -1Number of points at the top of the LDC that are pinned and cannot be aggregated into blocks.
LDC Slicing Method-0In (0,1)Method used to slice the LDC into blocks.
LDC Type-1In (1,2,3,4,7)Create one LDC for each period of this type in the horizon.
LDC Weight a-0LDC weighting polynomial function ‘a’ parameter.
LDC Weight b-1LDC weighting polynomial function ‘b’ parameter.
LDC Weight c-0LDC weighting polynomial function ‘c’ parameter.
LDC Weight d-0LDC weighting polynomial function ‘d’ parameter.
New Entry Capacity Mechanism-0In (0,1,2)Capacity payment mechanism.
New Entry Driver-0In (0,1,2,3)New entry driver.
New Entry Time Lagmonth12>= 0Lag time for entrepreneurial entry.
Outage IncrementMW10>= 1Generator outage bin size in convolution.
Pricing Method-0In (0,1)Type of generator pricing used in MT Schedule.
Reduced Sample Count-4>= 1Statistically reduce the Sample Type periods to at most this number of samples each year.
Reduction Relative Accuracy-1Between 0 And 1Stop sample reduction when the accuracy of the reduced sample set reaches this level.
Reliability Min Contiguous Blockh0>= 0For reliability based sampled chronology ensure sampled periods are contained in contiguous blocks of at least this many hours.
Sample Type-2In (1,2,3,4)For Chronology = Sampled, take this type of sample.
Sampled Block Count-0>= 0Number of blocks modeled in each sample period (day/week) where zero means the original number of intervals.
Sampled Shallow Storage Cutoffh0>= 0For Chronology = Sampled and Sampled Shallow Storage Treatment = Custom, maximum storage duration in hours for shallow storage formulation.
Sampled Shallow Storage Treatment-1In (1,2,3)Sampled shallow storage treatment.
Sampling Interval-4In (-1,2,3,4,7)For Chronology = Sampled, take Sample Type samples in each of these intervals of time.
Start Cost Amortization Periodh0>= 0Number of hours over which generator start costs are amortized.
Step Link Mode-0In (0,1,2)Controls how the solutions of each step are linked together.
Step Type-4In (1,2,3,4,7)Each simulation step will span steps of this type.
Stochastic Algorithm-0In (0,1)Algorithm invoked by the Stochastic Method when a scenario tree is present.
Stochastic Method-0In (0,1,2,3)Stochastic optimization method for MT Schedule.
Storage Formulate Head EffectsYes/No-1In (0,-1)If storage head effects should be formulated in MT Schedule.
Use Effective Load ApproachYes/No0In (0,-1)If MT Schedule uses the effective load approach.
Write Bridge Text FilesYes/No0In (0,-1)If bridge information such as constraint decomposition and storage targets should be written to text files.