This page documents the PLEXOS Transmission class attributes and their default values, validation rules, and descriptions.

To look at the open access PLEXOS documentation, go to PLEXOS Transmission Index.

Use this reference when setting configuration values through PlexosDB attributes, for example with add_attribute, get_attribute, and list_attributes.

NameUnitsDefault ValueValidation RuleDescription
Allow Dump EnergyYes/No-1In (0,-1)Model Dump Energy in OPF
Allow Unserved EnergyYes/No-1In (0,-1)Model Unserved Energy in OPF
Bound Node Phase AnglesYes/No0In (0,-1)If the Node [Phase Angle] values are subject to bounds in absolute value.
Cache Transmission MatricesYes/No0In (0,-1)Cache the transmission matrices to disk for future use.
Calculate Node LPF from Load-0In (0,1)Automatically calculate Node LPF from input Load property
Commitment PTDF Threshold-0>= 0Minimum absolute value of PTDF coefficient in commitment solves.
Constraint Limit Penalty$/MWh-1Penalty for exceeding line and transformer limits.
Constraint Voltage ThresholdkV0>= 0Voltage level at which thermal limits are modelled.
Constraints EnabledYes/No-1In (0,-1)If transmission line constraints are enabled.
Contingency Limit Penalty$/MWh-1Penalty for exceeding contingency flow limits.
Contingency Monitoring Threshold%100Between 0 And 100Monitor only this percentage of most affected Line/Transformer/Interface flows.
Convergence Report Level-1In (0,1,2)Level of screen reporting during transmission convergence iterations (none, normal, verbose)
Detail-1In (0,1,2)Level of detail used in transmission modeling
Detect Non-physical LossesYes/No0In (0,-1)If non-physical losses should be detected (in the piecewise linear loss model) and removed via mixed-integer programming
Energy Balance Violation VariablesYes/No0In (0,-1)Include violation variables on the transmission system energy balance equations
Enforce Limits On Lines In InterfacesYes/No0In (0,-1)If lines and transformers in interfaces should have their limits enforced regardless of voltage
Enforce N-1 ContingenciesYes/No0In (0,-1)If N-1 contingencies should be automatically enforced.
Filter LimitsYes/No0In (0,-1)If transmission limits are filtered using extreme flows from MT Schedule
Flow PTDF Threshold-0.01>= 0Minimum absolute value of PTDF as coefficient in transmission flow constraints.
Formulate UpfrontYes/No0In (0,-1)If transmission constraints should all be formulated upfront rather than checked iteratively.
Interface Constraints EnabledYes/No-1In (0,-1)If interface constraints are enabled.
Interface Limit Penalty$/MWh-1Penalty for exceeding interface flow limits.
Internal VoLL$100000Between 0 And 1E+9Value of Lost Load used internally
Interruption SharingYes/No0In (0,-1)If region interruption sharing is activated.
Kron-reduced Model Input-0In (0,1)Input properties and files written out for Kron-reduced model.
Limit Bootstrap Initial Threshold-2>= 0Initial value of [Limit Threshold] during transmission constraint bootstrap phase.
Limit Bootstrap Threshold Decrement-0.25Between 0 And 1[Limit Threshold] decrement used for each iteration of transmission bootstrap phase.
Limit Threshold-0.95Between 0 And 1Line, Transformer, or Interface flow loading threshold above which limits are added.
LODF Threshold-0.03>= 0Minimum absolute value of LODF to be used in contingency flow constraints.
Loss Method-0In (0,1,3,4,5)Formulation method used to model transmission losses.
Loss Tolerance-1E-05>= 0Relative gap between real and modelled losses.
Loss Voltage ThresholdkV0>= 0Voltage level at which losses are modelled.
Losses EnabledYes/No0In (0,-1)If transmission losses are enabled.
Max Absolute Phase Anglerad6.28Between 0 And 6.28318530717958Maximum absolute value allowed for any Node [Phase Angle].
Max Embedded Loss Iterations-2>= 0Maximum number of iterations for removing embedded losses from load.
Max Limit Iterations-1000>= 0Maximum number of iterations during any one call to enforce transmission limits.
Max Loss Absolute Error-0>= 0Maximum allowed absolute error in the piecewise linear loss function.
Max Loss Iterations-50>= 1Maximum number of iterations for converging the losses.
Max Loss Relative Error-0>= 0Maximum allowed relative error in the piecewise linear loss function.
Max Loss Tranches-100>= 1Maximum number of tranches in piecewise linear line loss function.
MVA Base-100>= 0MVA base for AC line parameters.
N-1 Contingency Voltage ThresholdkV0>= 0Voltage level at which N-1 contingencies are automatically enforced.
OPF Method-0In (0,1)Method for solving optimal power flow.
PTDF Method-0In (0,1,2,3,4)Method for computation of shift factors
Reactance Cut-off-0Smallest allowable reactance when performing OPF.
Rental Method-0In (0,1)Method used to calculate transmission rentals
Report All Interregional FlowsYes/No-1In (0,-1)If line flows between regions should be reported regardless of kV.
Report All Interzonal FlowsYes/No-1In (0,-1)If line flows between zones should be reported regardless of kV.
Report EnabledYes/No-1In (0,-1)If transmission reporting is enabled.
Report Injection and Load NodesYes/No0In (0,-1)If all injection and load buses (nodes) are reported on (regardless of voltage)
Report Lines In InterfacesYes/No0In (0,-1)If all flows on lines selected interfaces are reported
Report Voltage ThresholdkV0>= 0Voltage level at which transmission reporting begins.
SCUC Constraint Voltage ThresholdkV0>= 0Voltage level at which SCUC line thermal limits are modelled.
SCUC EnabledYes/No0In (0,-1)If security constrained unit commitment (SCUC) is enabled
SCUC Interface Constraints EnabledYes/No0In (0,-1)If enabled interface constraints are monitored in SCUC.
USE Threshold%100Between 0 And 100Formulates the [Unserved Energy] variables on the top x% nodes (highest load).
Wheeling PTDF Threshold-0.05>= 0Minimum absolute value of PTDF as coefficient in wheeling definitions.
Write Kron-reduced ModelYes/No0In (0,-1)If write Kron-reduced model is enabled.
Zero Limit Treatment-0In (0,1)Treatment of AC elements with zero limits