Production Attributes Reference

This page documents the PLEXOS Production class attributes and their default values, validation rules, and descriptions.

To look at the open access PLEXOS documentation, go to PLEXOS Production Index.

Use this reference when setting configuration values through PlexosDB attributes, for example with add_attribute, get_attribute, and list_attributes.

NameUnitsDefault ValueValidation RuleDescription
Battery Station Aggregation Mode-0In (0,1,2)Automatically create Battery Station objects by aggregating Batteries
Capacity Factor Constraint Basis-0In (0,1)Basis for capacity factor constraints.
Cooling States EnabledYes/No-1In (0,-1)If generator unit cooling states are enabled
Dispatch by Battery StationYes/No-1In (0,-1)If batteries should be aggregated through manual or automatic battery stations for dispatch.
Dispatch by Power StationYes/No-1In (0,-1)If generators in power stations should be treated in aggregate for dispatch.
DP Capacity Factor Error Threshold%20>= 0Error in DP capacity factor compared to MT Schedule capacity factor below which the DP solution is accepted
DP Capacity Factor Threshold%20>= 0Minimum capacity factor for generators to be dispatched by the DP
Forced Outage Relaxes Min Down TimeYes/No0In (0,-1)If ramp constraints should all be formulated upfront rather than checked iteratively.
Formulate Ramp UpfrontYes/No-1In (0,-1)If ramp constraints should all be formulated upfront rather than checked iteratively.
Formulate UpfrontYes/No-1In (0,-1)If production constraints should all be formulated upfront rather than checked iteratively.
Fuel Use Function Precision-0>= 0Precision for calculation of linear approximation to fuel function.
Gas Demand Resolution-0In (0,1,2)Resolution of input gas demands
Heat Rate Detail-0In (0,1,2)Level of detail for Generator heat rate modelling
Heat Rate Error Method-2In (0,1,2,3,4)Method for handling non-convex heat rate functions.
Increment and DecrementYes/No-1In (0,-1)If simultaneous closure of increment and decrement bids/offers around a base is allowed
Integers in Look-ahead-1In (0,1,2)Controls when the look-ahead contains integers for unit commitment and other decisions.
Max Heat Rate Tranches-10Between 1 And 100Maximum number of tranches in the fuel function piecewise linear approximation
Min Heat Rate Tranche Size-0>= 0Minimum tranche size in fuel function piecewise linear approximation
Power Station Aggregation Mode-0In (0,1,2)Automatically create Power Station objects by aggregating Generators
Pump and GenerateYes/No-1In (0,-1)If pumped storage/battery is allowed to pump/charge and generate/discharge simultaneously
Ramping Constraints EnabledYes/No-1In (0,-1)If facility ramping constraints are modeled
Rounded Relaxation Commitment Model-0In (0,1)Determines if the unit commitment decisions are made centrally or by self-commitment
Rounded Relaxation End Threshold-0.75<= 1End value for [Rounding Up Threshold] when Rounded Relaxation is running self-tune.
Rounded Relaxation Start Threshold-0.25>= 0Start value for [Rounding Up Threshold] when Rounded Relaxation is running self-tune.
Rounded Relaxation Threshold Increment-0.05>= 0.01Increment value for [Rounding Up Threshold] when Rounded Relaxation is running self-tune.
Rounded Relaxation TuningYes/No0In (0,-1)If the Rounded Relaxation method should self-tune the [Rounding Up Threshold].
Rounding Up Threshold-0.5Between 0 And 1Threshold at which non-integers are rounded up.
Run Up and Down EnabledYes/No-1In (0,-1)If generator run up and run down are modeled
Start and Stop EnabledYes/No-1In (0,-1)If facility start up and shut down are modeled
Start Cost Method-0In (0,1)Method for handling start costs in the mathematical formulation (integrate into the formulation, or calculate ex-post)
Transitions EnabledYes/No-1In (0,-1)If generator transitions are modeled
Unit Commitment Heat Rate DetailYes/No-1In (0,-1)If modeling fully detailed heat rates for unit commitment. Otherwise perform a two-pass UC/ED.
Unit Commitment Optimality-0In (0,1,2,3)Unit commitment integerization scheme.
Warm Up Process EnabledYes/No-1In (0,-1)If modeling of Facility Warm Up Process is enabled